|

Return to Previous
Page
Mircom
manufactures and markets a full line of high quality
fire control and communication products dedicated to the
life safety and telephone access markets. Mircom is
committed to providing high quality, cost-effective and
innovative products that meet the demands of a growing
marketplace.
If you require further assistance,
please click
here, fill in the appropriate fields,
specify the subject, and push the send button. We will
respond to your inquiry in 1 to 2 business days.
Please click
the links below for product type:
SERIES 200 MICROPROCESSOR BASED LOW ZONE FIRE ALARM
CONTROL PANELS
CONVENTIONAL LOW ZONE FIRE ALARM CONTROL PANELS
SERIES 1000 MICROPROCESSOR BASED FIRE ALARM CONTROL
PANELS
FX-2000 INTELLIGENT ANALOG ADDRESSABLE FIRE ALARM
CONTROL PANEL
FX-2000 LOBBY CONTROL ENCLOSURES
Intelligent Analog Sensors and
Addressable Modules
FIRE ALARM DEVICES
SERIES 200
MICROPROCESSOR BASED LOW ZONE FIRE ALARM CONTROL PANELS
Mircom’s Microprocessor-Based Low Zone Fire Alarm
Control Panels are designed for small commercial,
residential, institutional and industrial occupancies.
Fully configurable using DIP switches, the Series 200
enable the user to configure the system to meet their
specific requirements.
|
 |
FA-201, FA-202 and FA-204
One,
Two or Four Zone Microprocessor-Based Fire Alarm
Control Panels
• One, Two or Four Class B (Style
B) Initiating Circuit(s)
• Two Class A/B (Style
Z/Y) Indicating Circuit - 1.25 Amps each
• Alarm
Verification on Initiating Circuits
• RS-485
Interface for Multiplexed Remote Annunciators
(FA-204 only)
• Easy configuration via DIP
switches |
| |
|
 |
FA-204E Four Zone Expandable to Eight Zone
Microprocessor-Based Fire Alarm Control Panel
• Four Class B (Style B) or
Two Class A (Style D) Initiating
Circuits. Expandable up to Eight Class B (Style
B) or Four
Class A (Style D) Initiating Circuits
• Two Class A/B (Style Z/Y) Indicating Circuits.
Expandable up to Four Indicating Circuits
• Alarm Verification on Initiating Circuits |
| |
|
 |
RA-200 Series Remote Multiplex Annunciators
Common Control Features,
Indicators and 8 or 16 Bi-Coloured LEDs
• LEDs automatically
configured for either Alarm or Supervisory to
match the Series 200 or Series 1000 fire alarm
control panels • Mounts to standard electrical
boxes |
| |
|
|
Series 200 System Accessories
DM-204 Four
Detection and Two Signal Adder module (for
FA-204E only)
DACT-100
Digital Alarm Communication Transmitter Dialer
Module PR-100 Polarity Reversal/City Tie Module
RM-204
Auxiliary Relay Module c/w four configurable
relays
RM-208
Auxiliary Relay Module c/w eight configurable
relays |
|
 |
CONVENTIONAL LOW ZONE
FIRE ALARM CONTROL PANELS
Mircom’s Conventional Low Zone
Fire Alarm Control Panels are designed for non-coded
fire alarm systems in small commercial, residential,
institutional and industrial occupancies.
 |
FA-101, FA-102 & FA-1025
One, Two or Five Zone Fire Alarm Panels
• One,
Two or Five Class B (Style B) Initiating
Circuit(s)
• One Class B (Style Y) Indicating Circuit -
1.25 Amps (Two Indicating Circuits on the
FA-1025)
• Zone Silence/Disconnect Switch
• Cabinet available in a beige color for the
Canadian market and red exterior for the U.S.
and
International markets
• Output for Remote Trouble Indicator
• Alarm and Trouble Contacts |
|
One to Five Zone System
Accessories
FA-102TR Flush Trim Ring for FA-10A, FA-102A &
FA-1025A
RTI-1 Remote Trouble Indicator for FA-101A,
FA-102A and FA-1025A
RA-105 Five Zone Remote Annunciator for
FA-1025A.
Comes complete with red alarm LEDs and mounts on
a single gang plate
MP-300 End of Line Plates
BA-104 12 Volt/ 4 AH Battery |
|
 |
SERIES 1000
MICROPROCESSOR BASED FIRE ALARM CONTROL PANELS
Mircom’s
Series 1000 Microprocessor-Based Fire Alarm Control
Panels are multi-zone units designed for maximum
flexibility and easy installation and operation. Fully
configurable using push buttons and DIP switches the
Series 1000 enables the user to configure the system to
meet their specific requirements.
 |
Features
• Large system capacity
• Modular design
• Each Initiating circuit can be configured as
Alarm, Supervisory,
Waterflow or Trouble
• Configurable Signal Silence Inhibit, Auto
Signal Silence, Two-Stage Operation and One Man
Walk Test
• RS-485 Interface for RA-1000 Multiplexed
Remote Annunciators
• Easy configuration via push buttons and DIP
switches on the front panel
• 6 Amp or 12 Amp power supplies available
• Two outputs for 4-wire resettable smoke power
supply
• Slide-in labels for zone identification
• Auxiliary relay contacts for Common Alarm,
Supervisory and Trouble
• Two enclosures available in a beige color for
the Canadian market |
| |
|
 |
FA-1008K Fire Alarm Kit
• 8 Class B (Style B) or 4
Class A (Style D) Initiating Circuits
• 4 Class A/B (Style Z/Y)
Indicating Circuits - 1.7 Amps each
• 6 Amp power supply •
RS-485 Interface for Remote Multiplexed
Annunciators
• Supports a maximum of 2
Adder modules and one Central Station module
•
Cabinet will support up to 17 AH batteries |
| |
|
 |
FA-1012K Fire Alarm Kit
• 12 Class B (Style B)
Initiating Circuits
• 2 Class B (Style Y) Indicating Circuits
• 5 Amp power supply
• RS-485 Interface for Remote Multiplexed
Annunciators
• Non-expandable fire alarm panel
• Cabinet will support up to 17 AH batteries |
| |
|
|
|
RA-1000 Remote Annunciators
Mircom’s RA-1000 multiplex annunciators provide
a large capacity of annunciation with the Series
1000 Fire Alarm Control Panels. The RA-1000
Remote Annunciators are UL, ULC, CSFM and MEA
Approved. |
|
|
|
 |
RAM-1032
Main Annunciator Chassis c/w
Common Control Features, Indicators and 32 Bi-Coloured LEDs |
|
|
|
 |
RAM-1016
Main Annunciator Chassis c/w
Common Control Features, Indicators and
16 Bi-Coloured LEDS (Non-expandable) |
|
|
|
 |
RAM-1048 Adder Annunciator Chassis c/w
48 Bi-Coloured LEDs |
|
 |
FX-2000
INTELLIGENT ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL
Mircom’s
FX-2000 Intelligent Analog Fire Alarm Control Panel is
designed to provide maximum flexibility of analog system
requirements while also providing easy installation and
operation at a cost-effective price.
 |
Features
• Large system capacity
• Modular design
• Each analog loop is capable of supporting 99
analog sensors and 99 addressable modules
• Base system supports 16 conventional hardwired
modules
• Four Class A/B (Style Z/Y) Indicating Circuits
rated for 1.7 Amps each
• Large 4 line by 20 character back-lit LCD
display with user friendly menu
• Front panel auto configure and/or computer
laptop programmable
• Four alarm queues with selector switches
• Queues available for Alarm, Supervisory,
Monitor and Trouble
• Common Control switches
and/or indicating LEDs for System Reset, Signal
Silence, Fire Drill, Acknowledge, General Alarm,
Lamp Test, A.C. On, Pre-Alarm and Ground Fault
• 16 zone configurable LED annunciator
• Three level password protection with field
programmable definition which enables the
installer to determine what functions are
accessible for each password level
• Two Event History Logs comprised of a 1000
Alarm History Log for alarm related events and a
2000 Event Log for all events.
• Auxiliary relay contacts for Common Alarm,
Common Supervisory and Common Trouble
• RS-232 output for remote system printer or CRT
• UL, ULC, CSFM and MEA Approved |
|
 |
|
Intelligent
Loop Controller Modules & Adder Hardwire Modules
Intelligent Adder Loop
Controller Modules
ALC-198S
Single Analog Loop Controller Module
ALC-396S Dual Analog Loop Controller
Module
ALC-H16 Hardwire Loop Controller Module
Adder Hardwire Modules
DM-1008A
Eight Initiating Circuit Module
SGM-1004A Four Indicating Circuit Module
RM-1008A Eight Relay Circuit Module
Auxiliary Adder
Modules
UDACT-100
Digital Communicator
PR-100 Polarity Reversal/City Tie Module |
|
|
FX-2000 Intelligent Programmable Modules
Mircom’s FX-2000
Intelligent Programmable Modules consist of
Remote Shared Displays, LED Annunciators,
Programmable Input Switch modules and Fan Damper
Control Modules. |
|
|
|
 |
RAX-LCD Remote Shared
Display
• Provides LCD annunciation
• Driver module for standard or reduced zone
annunciation
• Driver module for RAX-048, FDX-008 IPS-2424
and AGD-048 when mounted remotely |
|
|
|
 |
FDX-008 Fan Damper
Control Module
• Individual programmed
circuits for fan or damper control
• Three position selector switch for off, on and
auto
• Supervised for operation
• Connects to main panel or RAX-LCD Remote
Shared Display when mounted remotely
|
|
|
|
 |
RAM-1032 Main LED
Annunciator Module
• Provides 32 points of LED annunciation
• Sealed membrane-like buttons for common
control functions
• Slide-in labels for zone identification |
|
|
|
 |
RAX-048 Programmable
Zone LED Annunciator Module
• 48 programmable bi-coloured
LEDs
• Connects to the main panel or the RAX-LCD
Remote Shared Display when mounted remotely |
|
|
|
 |
IPS-2424 Programmable Input
Switches Module
• 24 programmable switches
• Switches operate in a toggle operation
• Indicates status of disconnected zones
• Connects to the main panel or the RAX-LCD
Remote Shared Display when mounted remotely |
|
|
|
 |
RAX-1048 Adder LED Annunciator Module
• Provides 48 additional
points of LED annunciation
• Connects to the RAM-1032 Main Annunciator
Module
• Slide-in labels for zone identification |
|
|
|
Graphic Annunciator Driver
Modules
MGD-032 Master Graphic Driver Module c/w
common control switch inputs and 32 supervised
outputs
MGDS-16/16 Master Graphic Driver Module
c/w common control switches, 16 programmable
zoned LEDs and 16 supervised outputs
AGD-048 Adder Graphic Driver Module c/w
48 supervised outputs |
| |
|
FX-2000
LOBBY CONTROL ENCLOSURES
Mircom’s
FX-2000 Lobby Control Enclosures are designed to mount
programmable modules such as the RAX-LCD, RAX-048,
FDX-008 and IPS-2424.
Intelligent Analog Sensors
and Addressable Modules
Mircom’s
Intelligent Addressable devices consist of UL/ULC
approved analog sensors and addressable modules.
 |
MIX-1251 Intelligent Low Profile
Analog Ionization Smoke Sensor
• Plug-in head (requires separate base)
• Rotary decimal switches for address setting |
 |
MIX-5251P/MIX-5251RP Intelligent Low
Profile Analog Thermal Sensor
• MIX-5251P Fixed Thermal Sensor
• MIX-5251RP Rate of Rise Sensor
• Plug-in head (requires separate base) |
 |
MIX-M500M/MIX-M502M Intelligent
Addressable Monitor Module
• Provides address for group of N.O. devices
• MIX-M502M allows for the use of conventional
2-wire smoke detectors |
 |
MIX-M500DM Intelligent Addressable
Dual Monitor Module
• Provides addresses for group of N.O. devices
• Class B wiring only |
 |
MS-400AD Addressable Pull Station
• Single action manual pull station
• Rotary decimal switches for address setting
• Available with additional N.O. or N.C. switch |
 |
MS-500AD Addressable Pull Station
• Single action manual pull station
• Key resettable
• Rotary decimal switches for address setting |
 |
MIX-2251 Intelligent Low Profile
Analog Photoelectric Smoke Sensor
• Plug-in head (requires separate base)
• Rotary decimal switches for address setting |
 |
DH-200P/DH-200RP Intelligent
Photoelectric Duct Detectors
• Innovair Duct Detector with telescoping
sampling tube
• DH-200RP is equipped with a relay |
 |
MIX-M500R Intelligent Addressable Relay
Module
• Provides two isolated sets of Form-C contacts
|
 |
MIX-M500S Intelligent Addressable
Supervised Control Module
• Provides supervised monitoring of signal
devices such as horns, strobes or bells
• Requires a 24 VDC power source |
 |
MIX-M501M Intelligent Addressable
Monitor Module
• Provides an address for a group of normally
open devices
• Class B wiring only |
 |
M500X Fault Isolator Module
• Protects the system against wire-to-wire short
circuits
|
|
 |
MIRCOM FIRE ALARM DEVICES
Mircom’s complete fire product line includes a wide
variety of fire alarm devices such as manual pull
stations, smoke and heat sensors, bells, mini-horns and
speakers.
 |
MS-400 Fire Alarm Pull Stations
• Standard single gang mount
• Extruded aluminum construction
• UL, ULC, CSFM and MEA Approved |
 |
MS-403 (Blue) MS-404 (Yellow)
Emergency Pull Stations
• N.O. and N.C. contacts
• Standard single gang mount
• Converts to Double Action
• UL, ULC, CSFM and MEA Approved |
 |
MIR-500 Photoelectric Smoke Sensor
• Low current consumption
• 2 and 4 wire models available
• Available with thermal sensor
• UL, ULC, CSFM and MEA Approved |
 |
DH-100 Innovair Duct Detectors
• 2 and 4 wire models available
• Telescoping sampling tube
• UL, ULC and FM Approved |
 |
TD-Series Fixed Temperature Heat
Detector
• Self restoring
• Low profile white exterior
• ULC Approved |
 |
MS-500 Key Resettable Fire Alarm Pull
Stations
• Standard single gang mount
• Key Resettable
• UL, ULC, CSFM and MEA Approved |
 |
Remote Trouble Indicator
• Universal Application
• UL, ULC, CSFM and MEA Approved |
 |
MIR-1400A Ionization Smoke Sensor
• 2-wire model
• Dual unipolar chamber
• Twist-on mounting bracket
• UL, ULC, CSFM, FM and MEA Approved |
 |
MIR-2400A Photoelectric Smoke Sensor
• Optical sensing chamber
• Low standby current
• Twist-on mounting bracket
• UL, ULC, CSFM and MEA Approved |
 |
MIR-600 Heat Detectors
• Fixed/Rate of Rise Temp.
• One or Two N.O. contacts available
• Low profile white exterior finish
• UL, ULC, CSFM, FM and MEA Approved |
 |
MH-Series Mini Horns
• Over 90 dBA @ 10 feet
• Silenceable/Non-Silenceable versions
• Available in red or off-white finish
• UL, ULC and CSFM Approved |
 |
SP-Series Speakers
• 4 and 8 inch speakers
• 25 and 70 volt line matching transformer
• Multiple power taps
• Fire retardant cone material
• ULC Approved |
 |
Series 200 Select-A-Horn, Strobes and
Horn/Strobes
• Low current draw
• Strobe field selectable for 15/75 or 30/120 cd
• UL, ULC, CSFM, MEA and FM Approved |
 |
SPS-Series Speaker-Strobes
• 4 inch speakers
• 25 and 70 volt line matching transformer
• Strobe field selectable for 15/75 or
30/120 cd
• ULC Approved |
 |
BL-Series Bells
• 6 and 10 inch bells
• Low current
• Polarized for DC supervision
• UL, ULC, CSFM and FM Approved |
 |
SP-Series Retrofit Speakers
• 4 inch speakers
• 25 and 70 volt line matching
transformer
• Mount over existing intercom stations
• ULC Approved |
 |
Electromagnetic Door Holders
• Surface, Recess, Semi-Flush and Floor mount
• Low current draw
• Dual voltage inputs
• UL, ULC and CSFM Approved |
 |
Fire Alarm Accessories
• Wire Guards
• Weather Stoppers
• End of line plate |

Copyright Serva-Lite Sales 2007 |